With the air suspension element ADS, natural frequencies between 1.5 and 3 Hz can be achieved during machine installation.
The highly flexible THERMOTEST diaphragm of the air suspension element ADS is characterized by its low inherent rigidity. Due to the available air volume and the highly flexible THERMOTEST diaphragm, natural frequencies between 1.5 and 3 Hz can be achieved.
Delivery contents of standard ICD pneumatic spring system
• 4 supporting points
- 3 pneumatic springs ADS type
Master with sensors and control valves
- 1 pneumatic spring ADS type
Slave without sensors and valves
• 1 control unit as 3-channel circuit board with USB cable
• Control cable for master elements
• Hose NW 4 with cross piece or T-pieces
• Power adapter
Options
• Control unit: circuit board in synthetic enclosure
• Connectors for control cable
• Filter-regulator unit consisting of pressure regulator, pressure gauge, filter, water separator
• Control cable: length of 3 control cables to customer specifications
• "Air Level Control" software for PC (Windows)
• Additional hose sections and connectors according to number of pneumatic springs
ICD system The basic version of the ICD pneumatic spring system is factory-programmed. However, the software allows varying the following parameters: reset accuracy, permissible deflection, response time, average level. These parameters can be viewed, freely chosen within wide limits, and permanently stored in the control unit. The values are retained even after a power failure. The factory default settings are documented in a datasheet.
ADS-ICD series
Dimension table
Dimensions in mm |
D |
Installation Height
H
mm |
Working Height
Ho
mm |
Ni |
A |
Load
(max.)
kN |
ADS 3 |
105 |
92 |
97 |
+/- 5 |
106 |
1.8 |
ADS 6 |
127 |
92 |
97 |
+/- 5 |
130 |
2.8 |
ADS 12 |
175/170 |
92 |
97 |
+/- 5 |
175 |
6.0 |
ADS 24 |
245 |
91 |
97 |
+/- 6 |
255 |
13.0 |
ADS 48 |
338 |
91 |
97 |
+/- 6 |
343 |
26.0 |
ADS 96 |
468 |
91 |
97 |
+/- 6 |
470 |
55.0 |
ADS 192 |
610 |
91 |
97 |
+/- 6 |
610 |
100.0 |
Control Unit
Overview of programmable parameters
• Reset accuracy: rough (+/- 0.5 mm, fine (+/- 0.1 mm), user-defined (+/- 0.01 mm ... 1 mm)
• Permissible deflection: wide (+/- 1.0 mm), narrow (+/- 0.5 mm), user-defined (+/- 0.01 mm ... 1.5 mm)
• Response time: fast (10 ms), slow (125 ms), user-defined (5 ms ... 125 ms)
• Level: Middle position (+/- 5 mm), fine adjustment with potentiometer and / or software
Applicanance