• Hotsale Vibration isolation Dampers mount
  • Hotsale Vibration isolation Dampers mount
  • Hotsale Vibration isolation Dampers mount
  • Hotsale Vibration isolation Dampers mount

Hotsale Vibration isolation Dampers mount

Color: Fixed
Customized: Non-Customized
Standard: International
Type: Bearing
Material: Stainless Steel
Load Range: Optional
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
VD441E
Natural Frequency
optional
Size
Optional
Product capacity
500000pcs/Months
Transport Package
Carton
Specification
Optional
Trademark
THERMOTEST
Origin
China

Product Description

 

Product Description

Viscoelastic dampers eff ectively reduce vibrations by converting kinetic energy into heat, thereby damping the movement of the system. Their design allows them to be used over a wide range of frequencies, however, the required type of viscoelastic damper depends on the planned application. The application range extends from process technology to the damping of individual machines or complete piping systems. Ambient temperatures from -30 °C to +110 °C as well as the most demanding environmental conditions (e.g. chemicals, dust- or salt-polluted atmospheres) do not present an obstacle.
The viscoelastic dampers and damping parameters are tested and monitored by our in-house test lab and independent test laboratories based on Safety Standard KTA 3205.3 issued by the Nuclear Safety Standards Commission (KTA).


Design

Viscoelastic dampers consist of a metal housing fi lled with a highly viscous medium. A piston connected to the upper connection plate can move freely in all directions within the medium. Either the upper or lower connection plate of the damper can be connected to the vibrating system, while the other plate is mounted on a fi xed abutment. Dampers cannot bear static loads. The dampers are protected against corrosion as standard according to ISO 12944 C3 (M). Tailor-made solutions can be provided to meet special customer requirements.

 

 

Hotsale Vibration isolation Dampers mount
Key parameters required to defi ne a damping solution are as follows:
· operating temperatures [°C], i.e. the lowest and highest expected temperature of the vibrating system and the environment
· resonance frequencies [Hz] of the vibrating system
· amplitude [mm] of the vibrating system
· mass [kg] of the vibrating system between two fi xed points
· cold / hot displacement
 Not all details are required. VICODA is pleased to provide support when selecting viscoelastic dampers.
Other services provided by VICODA include vibration measurements or simulations to get to the root cause of vibrations.




 

Product Parameters

 

Dimensions
 
Hotsale Vibration isolation Dampers mount
Hotsale Vibration isolation Dampers mount


 
 
VD 441E: nominal load, dimensions, weight
Type Nominal load
kN
E
mm
B
mm

mm
s
mm
d
mm
Weight
ca. kg
VD005441E 0.3 240 175 125 8 14 9
VD015441E 2.5 240 195 145 8 14 11
VD025441E 5 240 210 160 8 14 14
VD045441E 10 240 260 200 10 18 23
VD085441E 20 280 315 245 12 22 42
VD140441E 30 320 375 290 15 26 70
VD160441E 40 335 400 310 18 26 90
VD185441E 60 350 435 330 20 33 103
VD225441E 80 390 490 365 25 39 165
VD340441E 100 405 510 395 30 39 203
 
VD 441E: vertical damping parameters [kNs/m]  
Type Nominal load
kN
5 Hz 10 Hz 15 Hz 20 Hz 25 Hz 30 Hz 35 Hz
VD005441E 0.3 6,2 4,7 4,0 3,6 3,3 3,0 2,9
VD015441E 2.5 15,7 12,0 10,2 9,1 8,3 7,7 7,3
VD025441E 5 27,8 21,1 18,0 16,0 14,7 13,7 12,9
VD045441E 10 47,3 36,0 30,7 27,4 25,0 23,3 21,9
VD085441E 20 89,3 67,9 57,9 51,6 47,3 44,0 41,4
VD140441E 30 143,9 109,4 93,2 83,2 76,2 70,9 66,7
VD160441E 40 162,7 123,7 105,4 94,1 86,1 80,1 75,4
VD185441E 60 189,4 144,0 122,7 109,5 100,3 93,3 87,8
VD225441E 80 229,9 174,8 148,9 132,9 121,7 113,2 106,5
VD340441E 100 340,2 258,7 220,4 196,7 180,1 167,6 157,7
 
VD 441E: Horizontal damping parameters [kNs/m]  
Type Nominal load
kN
5 Hz 10 Hz 15 Hz 20 Hz 25 Hz 30 Hz 35 Hz
VD005441E 0.3 5,9 4,5 3,6 3,0 2,5 2,2 2,1
VD015441E 2.5 14,0 10,8 8,6 7,0 6,0 5,4 5,1
VD025441E 5 23,7 18,3 14,6 12,0 10,2 9,1 8,6
VD045441E 10 37,4 28,8 22,9 18,9 16,1 14,4 13,6
VD085441E 20 94,0 72,5 57,8 47,5 40,6 36,3 34,2
VD140441E 30 148,7 114,5 91,3 75,1 64,2 57,4 54,1
VD160441E 40 229,9 177,1 141,2 116,2 99,2 88,7 83,6
VD185441E 60 293,0 225,8 180,0 148,1 126,5 113,1 106,6
VD225441E 80 367,3 283,0 225,6 185,6 158,5 141,8 133,7
VD340441E 100 554,1 427,0 340,4 280,0 239,2 214,0 201,7

Detailed Photos

 

STEP-BY-STEP INSTALLATION OF DAMPER TYPES VD, VM AND VI (QUICK START GUIDE)
  Procedures Description
Hotsale Vibration isolation Dampers mount 1. Delivery
condition
Viscoelastic dampers can be delivered preset to 'cold position' (off set position).
This is guaranteed by transport locks securing the off set between the upper and
lower part of the damper. Unless ordered diff erently, the dampers are delivered
using the locking position (off set position x = 0; y = 0; z = 0}.
2. Installation The upper and lower connection plates are frictionally connected to the
piping system and steel construction. All transportation locks must be
removed subsequently.
3. Startup During startup, the relative position of each the upper and lower connection
plate changes to the pre-calculated hot load position. The damper should then
operate approximately in mid-position.
 

Company Profile

 

Hotsale Vibration isolation Dampers mount
Hotsale Vibration isolation Dampers mount
Hotsale Vibration isolation Dampers mount

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now